SLS 1

  • Menu: 4.9.30-3.1

Description

Define the settings of the SLS instances.

INFORMATION

If 3 encoders are evaluated with the MOVISAFE® CSA31A safety option and the FSoE or CIP Safety™ safety protocol is used for safe communication, at total of 4 of the 8 possible instances of the two safety subfunctions SLS and SSM can be parameterized.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following parameters are set:

Parameter

Meaning

Enable

Specifies whether the safety subfunction can be activated.

Fault response

Specifies the response to be performed when the limit speed is exceeded.

Monitoring delay t2

Time between activation of the safety subfunction and start of speed monitoring and ramp monitoring.

Limit speed

Speed at which the specified fault response is performed.

Ramp monitoring

Specifies how the deceleration ramp is monitored.

Deceleration a

The parameter can only be set if the deceleration ramp is monitored linearly or jerk-limited.

Monitored deceleration of the safety subfunction

Jerk time t3

The parameter can only be set if the deceleration ramp is not monitored jerk-limited.

Adjustment of the ramp type for the deceleration ramp of the safety subfunction

Inverter control

Specifies whether the safety option affects the inverter control.