Inverter control

  • Menu: 4.9.30-3.1-11
  • Index: 8706.19[0]

Description

Specifies whether the safety option affects the inverter control.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following settings are possible:

Setting

Meaning

Not active

The safety option does not interfere with the inverter control. The inverter is controlled via an external source, such as digital inputs, fieldbus or system bus.

Active with limitation

The safety option limits the following setpoints in the inverter:

  • Speed setpoint in the inverter to the difference between the limit speed and the limit speed distance of the safety subfunction
  • Deceleration setpoint in the inverter to the deceleration of the safety subfunction
  • Jerk time in the inverter to the jerk time of the safety subfunction with jerk-limited ramp monitoring

The limitation does not affect interpolating drive functions (such as FCB 10 Interpolated position control).

DefaultSetting

Not active