Stop state

  • Menu: 4.9.33-4.1-4
  • Index: 8706.66[0]

Description

Defines the state to which the drive is set upon activation of the safety sub-function.

The stop state is canceled by an increment enable. The safety sub-function can then initiate the monitoring of the limit position. The limit position is calculated with the Increment s2.

INFORMATION

The increment enable and the SLI safety sub-function must not be activated at the same time. In the case of simultaneous activation, the stop state is not canceled.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following settings are possible:

Setting

Meaning

STO drive safety function

When the SLI safety sub-function is activated, the STO safety sub-function is activated as the stop state.

SOS drive safety function

When the SLI safety sub-function is activated, the SOS safety sub-function is activated as the stop state.

No stop state

When the SLI safety sub-function is activated, the limit positions are calculated immediately and monitored by the safety sub-function. The increment enable has no function.

DefaultSetting

STO drive safety function