Inverter control
- Menu: 4.9.37-3.1-9
- Index: 8706.74[0]
Description
Defines whether the safety option intervenes in the control of the inverter when the safety sub-function is active.
The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.
The following settings are possible:
Setting | Meaning |
---|---|
Not active | The safety option does not interfere with the inverter control. The inverter is controlled via an external source, such as digital inputs, fieldbus, or system bus. |
Active with limitation | The safety option limits the acceleration setpoint in the inverter to the difference between the limit acceleration and the acceleration distance of the safety sub-function. |
DefaultSetting
Not active