F-DI 00

  • Menu: 4.9.75-5.1

Description

Define which safety sub-function is assigned to the safe digital input F‑DI.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following parameters are set:

Parameter

Meaning

Latching

When a safety sub-function is activated via the safe digital input, the lock prevents the safety sub-function from being deactivated by a signal change at the safe digital input (from signal state 0 to signal state 1).

The safe digital input remains locked until it is unlocked by another safe digital input or via safe process data.

Function 1

Defines the function or safety sub-function that is assigned to the safe digital input. Select the required function/safety sub-function from the drop-down list.

Function 2Function 4

Define the safety sub-function that is assigned to the safe digital input. Select the required safety sub-function from the drop-down menu.

For some combinations, multiple safety sub-functions can be assigned to one safe digital input.