SDI 1

  • Menu: 4.9.33-2.1

Description

Define the settings of the SDI instances.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following parameters are set:

Parameter

Meaning

Enable

Defines whether the safety sub-function can be activated.

Permanently activated

Specifies whether the permitted direction of movement of the respective instance is to be monitored permanently.

Monitoring cannot be deactivated at any point.

Permitted direction of movement

Specifies the permitted direction of movement of the drive.

Tolerance s1

Maximum possible distance against the permitted direction of movement during monitoring