SSR 1

  • Menu: 4.9.30-7.1

Description

Define the settings of the SSR instances.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following parameters are set:

Parameter

Meaning

Enable

Defines whether the safety sub-function can be activated.

Permanently activated

Specifies whether the actual speed is permanently monitored for the limits of the speed range of the respective instance.

Monitoring cannot be deactivated at any point.

Fault response

Specifies the response to be performed when the speed setpoint is outside the defined speed range.

Monitoring delay t3

Time period between activation of the safety sub-function and the start of speed range monitoring

Upper limit speed v6

Upper limit of the speed range beyond which the specified fault response is performed.

Lower limit speed v7

Lower limit of the speed range under which the specified fault response is performed.

Speed filter s3

Distance in which the speed can be outside the speed range without triggering a fault or state change of the safe process data.