Description
Define the settings of the SSR instances.
The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.
The following parameters are set:
Parameter | Meaning |
---|---|
Enable | Defines whether the safety sub-function can be activated. |
Permanently activated | Specifies whether the actual speed is permanently monitored for the limits of the speed range of the respective instance. Monitoring cannot be deactivated at any point. |
Specifies the response to be performed when the speed setpoint is outside the defined speed range. | |
Time period between activation of the safety sub-function and the start of speed range monitoring | |
Upper limit of the speed range beyond which the specified fault response is performed. | |
Lower limit of the speed range under which the specified fault response is performed. | |
Distance in which the speed can be outside the speed range without triggering a fault or state change of the safe process data. |