SSx 1
- Menu: 4.9.24-3.1
Description
Define the settings of the SSx variants.
The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.
The following parameters are set:
Parameter | Meaning |
---|---|
Enable | Defines whether the safety sub-function can be activated. |
Defines the final status of the safety sub-function. | |
Specifies how the deceleration ramp is monitored. | |
The parameter can only be set if the deceleration ramp is not monitored. Time after which the final state is activated. | |
The parameter can only be set if the deceleration ramp is monitored linearly or jerk-limited. Time period between activation of the SSx-r safety sub-function and the start of ramp monitoring | |
The parameter can only be set if the deceleration ramp is monitored linearly or jerk-limited. Monitored deceleration of the SSx-r safety sub-function | |
The parameter can only be set if the deceleration ramp is not monitored jerk-limited. Adaptation of the ramp type for the deceleration ramp of the SSx‑r safety sub-function | |
Defines whether the safety option intervenes in the control of the inverter when the safety sub-function is active. |