Selected final state
- Menu: 4.9.24-3.1-2
- Index: 8706.5[0]
Description
Defines the final status of the SSx safety sub-function.
The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.
The following settings are possible:
Setting | Meaning |
---|---|
After the SSx safety sub-function is executed, the STO safety sub-function is activated. This behavior corresponds to the SS1 safety sub-function. | |
After the SSx safety sub-function is executed, the parameterized SOS safety sub-function is activated. This behavior corresponds to the SS2 safety sub-function. INFORMATION: If an instance of the SSx safety sub-function is to be executed as an error response when safe communication is aborted, this setting must not be defined as the final status of the SSx instance. | |
/ | After the SSx safety sub-function is executed, the parameterized instance of the SLI safety sub-function is activated. INFORMATION: If an instance of the SSx safety sub-function is to be executed as an error response for a safety sub-function or when safe communication is aborted, this setting must not be defined as the final status of the SSx instance. |
DefaultSetting