Precontrol values via setpoint connection
- Menu: 4.4.10-1.1-1
- Index: 8510.1
Description
Specifies whether a speed setpoint and an acceleration precontrol value are specified for the inverter in addition to the position setpoint.
If the precontrol value is known directly with the setpoint and does not have to be calculated from previous values, faster compensation can be achieved. The precontrol value must match exactly the setpoint change and be transferred with the same process data cycle as the setpoint.
The following settings are possible:
Setting | Meaning |
---|---|
0 (no) | The precontrol values are calculated based on the change of the position setpoint. |
1 (yes) | The values from the parameters Speed und Acceleration precontrol (parameter group Setpoints > Setpoint value connection) are adopted. |
DefaultSetting
0 (no)