"Use only ""maximum positive speed"" parameter"
- Menu: 4.4.9-1.5-1
- Index: 8509.8
Description
Specifies whether the positive speed value from the profile value connection is used as a limit value in FCB 09 for both the positive and negative speed.
Setting | Meaning |
---|---|
0 (no) | When positioning, different speeds are used for the 2 directions. |
1 (yes) | When positioning, the value of the Maximum positive speed parameter from the parameter group Setpoints > Profile value connection is also defined as the maximum negative speed. This means that only one channel of the profile value connection is used. This setting is used for the general process data profile of SEW‑EURODRIVE. |
DefaultSetting
0 (no)