Maximum positive speed

  • Menu: 4.2.12-1.1

Description

Limit value of the speed profile value.

The following parameters are set:

Parameter

Meaning

Source

Specifies the source from which the limit value for the maximum speed in positive direction of movement is retrieved.

PO data format

The parameter specifies the data format of the process output data word if a process output data word was selected as the source of the setpoint.

The process output data words are data sources with a word width of 16 bits and can be combined to a 32-bit value using the data format. This parameter has no effect on data sources with a word width of 32 bits and is not displayed.

Value

Current limit value of the speed profile value that is used in the following drive functions:

  • FCB 07 Torque control
  • FCB 08 Interpolated torque control
  • FCB 09 Position control

If the Local value setting has been specified for the Source parameter, the user can specify the value locally. The local value is stored in a non-volatile memory.