Analog setpoint source
- Menu: 4.2.10-1.2-1
- Index: 8354.25
Description
Specifies from which source the analog setpoint is retrieved. The settings depend on the device.
The following settings are possible:
- No source
- Analog input AI 1
- Analog input AI 2
- Analog input AI 3
- Sum: AI 2 + AI 3
- Analog input AIO 01
- Analog input AIO 02
The analog setpoints are set and scaled depending on the device under Inputs/outputs > Basic unit > Analog input AI 1 oder Inputs/outputs > I/O card > Analog input AI.
DefaultSetting
No source