Direction of rotation reversal

  • Menu: 4.9.14-1.50-1
  • Index: 8362.2

Description

Defines whether the direction of rotation reversal is activated.

In order for the process values in the safety option to have an identical sign to the process values in the inverter, the parameter must be set in the same way as the Direction of rotation reversal parameter in the drive train configuration.

If it has a different setting, a message is displayed in the Assist CS.. tool.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following settings are possible:

Setting

Meaning

Off

Direction of rotation reversal is not active.

On

Direction of rotation reversal is active.

DefaultSetting

Off