Reference offset s1
- Menu: 4.9.40-1.2-1
- Index: 8707.51[0]
Description
The parameter is displayed when direct referencing is enabled.
Distance between reference point and machine zero. Direct referencing is executed at this position.
For encoders that are involved in the positioning, the reference offset is transferred to the safety option (in the parameter group Diagnostics > MOVISAFE® CS.. > Encoder evaluation) as the absolute position of the encoder.
Reference point | |
Machine zero | |
s1 | Reference offset |