Maximum tolerance position
- Menu: 4.9.14-5.10-1
- Index: 8707.10[0]
Description
The parameter is displayed when 2 encoders are used for positioning.
The following cases can occur:
- If both encoders are set to Process value and the encoder values are within the configured tolerance range, the mean value is formed from the two encoder values. The mean value is used in the safety sub-functions for monitoring.
- When calculating the response time, half of the tolerance values must be taken into account.
- If one encoder is set to Process value and another encoder is set to Comparison value, the difference in both encoder values must be within the configured tolerance range. The process value is used in the safety sub-functions for monitoring.
- When calculating the response time, the respective tolerance values must be taken into account.