Position

  • Menu: 4.9.14-2.1-2
  • Index: 8708.70[0]

Description

Specifies whether the encoder values are used to determine the position.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following settings are possible:

Setting

Meaning

Not used

The encoder values are not used to determine the position.

Process value

The encoder values are used as process values for monitoring the safety sub-functions.

Comparison value

The encoder values are comparison values for the values of the encoder that is set to Process value.

DefaultSetting

Not used