Activation by SBT clearance

  • Menu: 4.9.70-2.3-1
  • Index: 8712.10[0]

Description

Defines how the brake test is activated.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following settings are possible:

Setting

Meaning

1 (yes)

The brake test is activated by the "SBT clearance" signal via a safe digital input F‑DI or via the safe process data of the higher-level safety controller.

0 (no)

The brake test is activated when both the "SBT clearance" signal and the "SBT enable" signal are present.

The "SBT clearance" signal is set via a safe digital input F‑DI or via the safe process data of the higher-level safety controller.

The "SBT enable" signal is set via a non-safe digital input of the inverter or via the non-safe process data of the higher-level controller.

DefaultSetting

1 (yes)