Connection type

  • Menu: 4.9.6-4.1-2
  • Index: 8704.4[0]

Description

Specifies the connection type.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following settings are possible:

Setting

Meaning

1-channel

The two safe digital inputs F‑DI can be used separately as an NC contact or NO contact.

2-channel equivalent

The logical connection of the two safe digital inputs F-DI has the logical value 1 if the same signals are applied to the two digital inputs.

The two safe digital inputs provide either an NC function or an NO function.

2-channel non-equivalent

The logical connection of the two safe digital inputs F-DI has the logical value 1 if different signals are applied to the two digital inputs.

One safe digital input provides an NC function and the other safe digital input provides an NO function.

DefaultSetting

2-channel equivalent