Line diagnostics

  • Menu: 4.9.6-2.1-1
  • Index: 8704.1[0]

Description

Defines whether the detection of interference voltages and crossfaults on the safe digital input F‑DI is activated by test pulses of the sensor supply.

In order to use the line diagnostics function correctly, the Sensor supply pulsing parameter for the sensor supply must be active.

If a short circuit or crossfault is detected on the safe digital input, error E‑60.3 is issued. Safe digital input: F‑DI 0. Crossfault is triggered.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following settings are possible:

Setting

Meaning

Active

Line diagnostics is running.

If the Sensor supply pulsing parameter of the sensor supply is inactive, the configuration of the parameters cannot be loaded to the device. A plausibility error is triggered.

INFORMATION: Observe the notes and warnings regarding crossfault monitoring in the manual of the respective safety option.

Not active

Line diagnostics is not performed.

The setting of the Sensor supply pulsing parameter of sensor supply has no effect.

DefaultSetting

Active