Response to fast power-off detection
- Menu: 4.6.9-1.2-1
- Index: 8351.1
Description
Specifies how the inverter responds to a violation of the limit value specified in the DC link level for fast power-off detection parameter.
The following settings are possible:
Setting | Meaning |
---|---|
No response | The event is ignored. |
Application stop + output stage inhibit | The drive stops subject to speed control with the value of the Deceleration parameter (parameter group Monitoring functions > Limit values). The output stage is inhibited when motor standstill is reached. If a brake is installed, it is applied or the DynaStop® function is activated. |
Emergency stop + output stage inhibit | The drive stops subject to speed control with the value of the Emergency stop deceleration parameter (parameter group Monitoring functions > Limit values). The output stage is inhibited when motor standstill is reached. If a brake is installed, it is applied or the DynaStop® function is activated. |
Output stage inhibit | The output stage is inhibited immediately. If a brake is installed, it is applied or the DynaStop® function is activated. The drive is stopped in a non-controlled manner. |
DefaultSetting
Output stage inhibit