Operating mode
- Menu: 4.4.18-1.2-1
- Index: 8518.2
Description
Specifies how to further proceed with the result of rotor position identification (parameter Measured encoder offset).
The following settings are possible:
Setting | Meaning |
---|---|
Deactivated | The value is displayed, however, it cannot be adopted. This setting is used for control purposes. |
Manual | In order to accept the value after the measurement has been completed, the Write setting must be defined manually for the Write control parameter. The value is saved in the location defined in the Storage location parameter. |
Automatic | After the measurement is completed, the value is automatically written to the inverter. The value of the Fixed offset parameter is only adopted once this setting has been defined for the parameter. INFORMATION: If Encoder is set for the Storage location parameter, the value is not adopted and the motor cannot be moved. |
DefaultSetting
Manual