Go to home position
- Menu: 4.4.12-3.1
Description
The parameter is used for the following reference travel types:
- Zero pulse – negative direction
- Reference cam – negative end
- Reference cam – positive end
- Limit switch positive
- Limit switch negative
- Reference cam flush – limit switch positive
- Reference cam flush – limit switch negative
- Fixed stop positive
- Fixed stop negative
Specifies the position that is approaced after referencing.
The following settings are possible:
Setting | Meaning |
---|---|
0 (no) | The drive stops at the reference point. |
1 (yes) | The drive moves from the reference point at Homing speed [v3] to the position specified in the Home position parameter. |
DefaultSetting
0 (no)