Go to home position

  • Menu: 4.4.12-3.1

Description

The parameter is used for the following reference travel types:

  • Zero pulse – negative direction
  • Reference cam – negative end
  • Reference cam – positive end
  • Limit switch positive
  • Limit switch negative
  • Reference cam flush – limit switch positive
  • Reference cam flush – limit switch negative
  • Fixed stop positive
  • Fixed stop negative

Specifies the position that is approaced after referencing.

The following settings are possible:

Setting

Meaning

0 (no)

The drive stops at the reference point.

1 (yes)

The drive moves from the reference point at Homing speed [v3] to the position specified in the Home position parameter.

DefaultSetting

0 (no)