"Use ""operating mode"" control bit"
- Menu: 4.4.9-1.4-1
- Index: 8509.9
Description
Specifies whether the control bits are used that have been parameterized accordingly in the digital inputs or control words.
The following settings are possible:
Setting | Meaning |
---|---|
0 (no) | Positioning is carried out using the operating mode defined in the Operating mode parameter. |
1 (yes) | Positioning starts only with the set control bit. Either bits of the digital inputs (parameter group Inputs/outputs > Basic unit/I/O card) or bits of the control words (parameter group Setpoints > Control word.) must be parameterized to FCB 09 Position control – operating mode bit. as the control bit. The control bit is interpreted as a decimal number and corresponds to the different operating modes that can be defined in the Operating mode parameter:
The operating mode defined by the control bit is applied independently of the setting in the Operating mode parameter. |
DefaultSetting
0 (no)