Stop setpoint

  • Menu: 4.4.5-1.2

Description

Using the stop by setpoint function, the drive can be enabled or stopped automatically depending on the speed setpoint. The speed setpoint is compared with a stop setpoint and a start offset value.

AL

Application limit Positive speed

-AL

Application limit Negative speed

SW1

Stop setpoint

-SW1

-Stop setpoint

SW2

Stop setpoint + Start offset

-SW2

-Stop setpoint - Start offset

  • The drive is enabled under the following condition:
  • |setpoint| > SW2
  • An enabled drive remains enabled as long as the effective setpoint is above the Stop setpoint value.
  • The drive is stopped with active deceleration setpoint under the following condition:
  • |setpoint| < SW1
  • Once the drive has stopped, it behaves as specified in the Behavior at standstill parameter.