Activation
- Menu: 4.4.5-1.1
Description
Specifies whether the stop by setpoint function is activated.
Using the stop by setpoint function, the drive can be enabled or stopped automatically depending on the speed setpoint. The speed setpoint is compared with a stop setpoint and a start offset value.
AL | Application limit Positive speed |
-AL | Application limit Negative speed |
SW1 | Stop setpoint |
-SW1 | -Stop setpoint |
SW2 | Stop setpoint + Start offset |
-SW2 | -Stop setpoint - Start offset |
- The drive is enabled under the following condition:
- |setpoint| > SW2
- An enabled drive remains enabled as long as the effective setpoint is above the Stop setpoint value.
- The drive is stopped with active deceleration setpoint under the following condition:
- |setpoint| < SW1
- Once the drive has stopped, it behaves as specified in the Behavior at standstill parameter.
The following settings are possible:
Setting | Meaning |
---|---|
0 (no) | The stop by setpoint function is inactive. The speed setpoint is adopted within the application limits. |
1 (yes) | The stop by setpoint function is active. The drive is enabled or stopped automatically depending on the speed setpoint. |
INFORMATION

SEW‑EURODRIVE recommends to activate the stop by setpoint function when using hoists without motor encoder feedback.
DefaultSetting
0 (no)