Source
- Menu: 4.2.12-3.1-1
- Index: 8377.100
Description
External torque limitation allows to further reduce the torque limit using an analog input. A torque limit of 0 to 100% of the torque limit that is currently effective for the profile value connection can be defined. The value at the analog input must be between 0 and 100% via analog input scaling.
Specifies the source from which the external torque limiting is retrieved.
The following settings are possible:
Setting | Meaning |
---|---|
No source | External limiting is not used. |
Analog input AI 1 – 3 | Limit value the analog input (parameter Scaled value) from the parameter group Inputs/outputs > Basic unit/I/O card |
Sum: AI 2 + AI 3 | Sum of the limit values at the analog inputs (parameter Sum of analog inputs AI2 + AI3) from the parameter group Inputs/outputs > I/O card |
Analog input AIO 01 – 02 | Limit value at the configurable analog input (parameter Scaled value) from the parameter group Inputs/outputs > Basic unit |
DefaultSetting
No source