Source

  • Menu: 4.2.12-3.1-1
  • Index: 8377.100

Description

External torque limitation allows to further reduce the torque limit using an analog input. A torque limit of 0 to 100% of the torque limit that is currently effective for the profile value connection can be defined. The value at the analog input must be between 0 and 100% via analog input scaling.

Specifies the source from which the external torque limiting is retrieved.

The following settings are possible:

Setting

Meaning

No source

External limiting is not used.

Analog input AI 1 – 3

Limit value the analog input (parameter Scaled value) from the parameter group Inputs/outputs > Basic unit/I/O card

Sum: AI 2 + AI 3

Sum of the limit values at the analog inputs (parameter Sum of analog inputs AI2 + AI3) from the parameter group Inputs/outputs > I/O card

Analog input AIO 01 – 02

Limit value at the configurable analog input (parameter Scaled value) from the parameter group Inputs/outputs > Basic unit

DefaultSetting

No source