Source

  • Menu: 4.2.11-1.2-1
  • Index: 8376.11

Description

Specifies from which source the setpoint is retrieved.

The following settings are possible:

Setting

Meaning

Local value

Local setpoint specifiec by the user

Fixed setpoints – speed

Fixed speed setpoint from the parameter group Fixed setpoints. The active fixed setpoint depends on the configuration of fixed setpoint processing.

PO data word 1 – 16

Process output data word specified by the higher-level controller via bus communication

Data Flexibility output data 1 – 32

Reserved for data the of MOVIKIT® software module of the Drive module group

Analog input AI 1 – 3

Setpoint at the analog input (parameter Scaled value) of the parameter group Inputs/outputs > Basic unit/I/O card

Sum: AI 2 + AI 3

Sum of the setpoints at the analog inputs (parameter Sum of analog inputs AI2 + AI3) of the parameter group Inputs/outputs > I/O card

Analog input AIO 01 – 02

Setpoint at the configurable analog input (parameter Scaled value) of the parameter group Inputs/outputs > Basic unit

Sum: AI 1 + AIO 01

Sum of the setpoints at analog input AI 1 and at the configurable analog input AIO 01 of the parameter group Inputs/outputs > Basic unit

DefaultSetting

Local value