Save setpoint

  • Menu: 4.2.10-6.1-1
  • Index: 8369.2

Description

Specifies the storage behavior of the setpoint generated by the motor potentiometer function. Setpoints can only be changed when the inverter is enabled.

With the motor potentiometer function, a speed setpoint is generated by 2 binary signals. One binary signal increases the setpoint and the other binary signal decreases it.

The following settings are possible:

Setting

Meaning

0 (no)

The setpoint of the motor potentiometer is not saved.

The motor potentiometer starts with the setpoint that is valid at the moment of switching to the motor potentiometer function.

The limit values specified under the parameter group Monitoring functions > Limit values cannot be exceeded.

1 (yes)

The setpoint of the motor potentiometer is saved in a fail-safe manner 2 s after the last change.

The motor potentiometer starts with the saved value regardless of the setpoint that was previously active.

DefaultSetting

0 (no)