Error mask

  • Menu: 4.9.13-7.68-1
  • Index: 8599.26

Description

The parameter is displayed if the following conditions are met:

  • The encoder parameters are adopted from the drive train configuration.
  • The encoder uses one of the following interfaces for data transmission: SSI or SSI combi
  • For an encoder connected to the SSI combination box, the SSI track is evaluated.

Screen in which bits set to 1 are evaluated as error bits. If incorrect bits are set to 1 in the screen, position bits might be evaluated incorrectly as error bits.

SEW‑EURODRIVE recommends that you do not change the default value.