Motor protection

  • Menu: 4.1.1-5.5-1
  • Index: 8852.8

Description

Startup via DIP switches becomes active if no startup has yet been saved on the memory module using the following startup types:

  • Automatically via motors with digital motor integration
  • Manually via MOVISUITE® or a CBG.. keypad

An already completed startup can only be reset by restoring the delivery state.

Observe the information in the operating instructions of the respective device when replacing the device.

Position of DIP switches S3/5 and S3/6 that define the temperature sensor for motor protection.

For a description of the individual functions of the DIP switches, refer to the operating instructions of the respective device. You can download the documentation from the SEW-EURODRIVE website (www.sew-eurodrive.com) in various languages.

The following display values are possible:

Setting

Meaning

No sensor

The DIP switches are in the following position:

  • DIP switch S3/5 – position 0
  • DIP switch S3/6 – position 0

INFORMATION: If no temperature sensor is available, basic temperature protection is ensured via the firmware functions of the inverter.

PK (Pt1000)

The DIP switches are in the following position:

  • DIP switch S3/5 – position 1
  • DIP switch S3/6 – position 0

TF

The DIP switches are in the following position:

  • DIP switch S3/5 – position 0
  • DIP switch S3/6 – position 1

TH

The DIP switches are in the following position:

  • DIP switch S3/5 – position 1
  • DIP switch S3/6 – position 1