F-DO 00

  • Menu: 4.9.9-3.1

Description

Digital outputs F‑DO of the safety option.

The parameter setting is specified in the Assist CS.. tool. In MOVISUITE®, the specified setting is only displayed. This description refers to the Assist CS.. tool.

The following parameters are set:

Parameter

Meaning

Connection type

Specifies the connection type of the safe digital outputs.

Maximum test duration t1

Maximum test duration for output diagnostics with variable test duration. The variable test duration can be set to different actuators (brake, cylinder, etc.).

Wire break detection

Specifies whether the detection of interruptions in the output circuit is activated.