Status
- Menu: 6.4.26-5.1-1
- Index: 8700.101[0]
Description
Indicates that test mode is active. Test mode suppresses inverter control.
When test mode is active, the limit violation of a safety sub-function can be tested.
Test mode can be activated as follows:
- Via a safe digital input F‑DI
- Via safe process data
- In the Assist CS.. tool