SSx final state
- Menu: 6.4.17-2.17
Description
Indicates that the STO safety sub-function was activated after executing the SSx safety sub-function (variant SS1-t or SS1-r) as the final status.
- In the case of the SS1-t safety sub-function, the final status is activated after the monitored time period has elapsed.
- In the case of the Ss1-r safety sub-function, the final status is activated after the deceleration ramp has been monitored without errors and the minimum speed is reached (Minimum speed for speed function parameter in the Assist CS.. tool in the parameter group Basic settings).