Show fault memory

  • Menu: 6.4.6-1.2

Description

Ring memory in which the last 50 error states and messages of the safety option are stored remanently along with the corresponding timestamps. Messages do not trigger an error response directly.

The events can be transferred to an external editor if necessary. To do so, right-click to open the context menu for the fault memory and select Copy.

The following display values are possible:

Setting

Meaning

Pos

Position of the event

The most recent event always appears at position 0. In the case of more than 50 events, the first event to occur is discarded.

Info

Category of the event as a symbol

Error message

Number and text of the event

Internal fault

Used for internal purposes.

Operating hours

Current timestamp at the time of the event

Instance

Instance of the safety sub-function that was triggered or of the encoder that reported an event.