Device status
- Menu: 6.3.6-4.1-1
- Index: 8345.7 (Bitmaske: 0x00000000)
Description
Indicates the device status at the time when the fault occurred in bit-coded format. The individual bits correspond to the status bits of the parameter group Status > Device status:
- Bit 0 – Ready
- Bit 1 – Output stage enabled
- Bit 2 – Setpoints active
- Bit 3 – Drive train 1 active
- Bit 4 – Drive train 2 active
- Bit 5 – Limits active
- Bit 6 – Active drive referenced
- Bit 7 – "Safety card in ""RUN"" state "
- Bit 8 – Manual mode active
- Bit 9 – Configuration state
- Bit 10 – Power ON
- Bit 11 – Safety card controls inverter if safety function is activated
- Bit 12 – Prioritized terminal control active
- Bit 13 – Manual mode/local mode active
- Bit 14 – Brake released/DynaStop® disabled
INFORMATION