Absolute, field-generating current d-component – instantaneous value

  • Menu: 6.2.2-1.7-1
  • Index: 8364.120

Description

Instantaneous value of the current amplitude component in the rotor flux direction. In asynchronous motors, the field-generating current corresponds to the magnetization current. In stationary operation, this is a zero-frequency quantity.

The apparent output current is calculated from this value according to the following formula:

I2_eff

Rms value of the apparent output current

Id_amplitude

Amplitude value of the field-generating current

Iq_amplitude

Amplitude value of the torque-generating current