Activate startup state
- Menu: 6.1.1-1.10-1
- Index: 8332.5
Description
Some parameters can only be changed in startup state. MOVISUITE® prompts you to activate startup state if you want to change a parameter that requires startup state.
Specifies whether the startup parameters of the inverter can be changed.
The following settings are possible:
Setting | Meaning |
---|---|
Yes | The drive stops at the application limit and disables the output stage. The startup parameters of the inverter can be changed. Startup state can only be exited with the setting No. |
No | When an active startup state is exited (setting Yes), the changes made to the startup parameters are transferred from MOVISUITE® to the inverter. If the enable is still granted, the drive will be enabled. In other cases, this setting has no function. |
DefaultSetting
No