Cam window 1 – left limit
- Menu: 4.5.3-6.1-1
- Index: 8577.50
Description
Left limit of the cam window.
Example: Dependence on the scaling of the user unit
For sources that are scaled by user units, the limit value is calculated from the raw value of the selected source.
The raw value is the measured source value without units scaled with the decimal places of the user unit:

Source value | Size from the Data source parameter without user unit |
Decimal places of the user units | Defined by the user in the Number of decimal places parameter (parameter group Drive trains > Drive train DT. > User unit). |
If Actual position in user units is set in the Data source parameter, for example, and a cam is to be created in the range 1 to 4 mm, the following limit values must be entered:
Actual position | Left limit | Right limit | |||
---|---|---|---|---|---|
Unit | Number of | Raw value | Scaled value | Raw value | Scaled value |
mm | 3 | 1000 | 1000 | 4000 | 4000 |
mm | 2 | 100 | 1.00 | 400 | 4.00 |