Forcing

  • Menu: 4.5.3-3

Description

The switching signal of the cam track can be influenced by forcing settings and polarity settings. The switching signal is derived from the result bit of the cam track (actual position inside or outside the cam window) by logical linking of the settings.

CT

=

Cam track

Result bit of the cam track

Force-on mask

Force-off mask

Polarity mask

Result (switching signal)

0

0

0

0

0

0

0

0

1

1

0

0

1

0

0

0

0

1

1

1

0

1

0

0

1

0

1

0

1

0

0

1

1

0

0

0

1

1

1

1

1

0

0

0

1

1

0

0

1

0

1

0

1

0

0

1

0

1

1

1

1

1

0

0

1

1

1

0

1

0

1

1

1

0

0

1

1

1

1

1