Mode
- Menu: 4.5.1-1.1
Description
Mode of the touchprobe function. The touchprobe channel is only active when one of the modes is activated.
The following settings are possible:
Setting | Meaning |
---|---|
Single trigger | Specifies that a trigger is activated once. A new trigger can only be initiated after switching the single trigger off and on again. If Auto restart mode is selected, the one-time trigger is no longer taken into consideration. |
Auto restart | Specifies that the trigger is automatically reactivated after triggering. If this mode is selected, the Single trigger mode is no longer taken into account. |
INFORMATION

The mode can also be selected via a bit of the digital inputs (parameter group Inputs/outputs > Basic unit/I/O card) or a bit of the control words (parameter group Setpoints > control word.) that is parameterized to Touchprobe./mode/single trigger or Touchprobe./mode/restart automatically.
The setting via the digital input or the control word has priority over the setting of this parameter.