Mode

  • Menu: 4.5.1-1.1

Description

Mode of the touchprobe function. The touchprobe channel is only active when one of the modes is activated.

The following settings are possible:

Setting

Meaning

Single trigger

Specifies that a trigger is activated once. A new trigger can only be initiated after switching the single trigger off and on again.

If Auto restart mode is selected, the one-time trigger is no longer taken into consideration.

Auto restart

Specifies that the trigger is automatically reactivated after triggering.

If this mode is selected, the Single trigger mode is no longer taken into account.

INFORMATION

The mode can also be selected via a bit of the digital inputs (parameter group Inputs/outputs > Basic unit/I/O card) or a bit of the control words (parameter group Setpoints > control word.) that is parameterized to Touchprobe./mode/single trigger or Touchprobe./mode/restart automatically.
The setting via the digital input or the control word has priority over the setting of this parameter.