Source

  • Menu: 4.2.1-1.1-1
  • Index: 8366.4

Description

Specifies the source from which the process data are retrieved and output.

The following settings are possible:

Setting

Meaning

No source

No process data exchange with a higher-level controller. The inverter is controlled via digital inputs or optionally via analog inputs.

CBus

The values of the process data are retrieved from the CBus interface.

Fieldbus

The values of the process data are retrieved from the fieldbus interface.

The values of the process data are retrieved from the EtherCAT®/SBusPLUS interface.

Standard bus system

The values of the process data are retrieved from the bus system of the inverter (fieldbus, CBus, or EtherCAT®/SBusPLUS).

If several bus systems are present in the inverter (e.g. fieldbus card in the MOVIDRIVE® technology application inverter), the fieldbus interface has priority over the other interfaces. The determined bus system is displayed in the Standard bus system parameter.

DefaultSetting

The setting depends on the device.